CDL/CDLF Type Stainless Steel Vertical Multistage Water Pressure Jockey and Booster Centrifugal Pump

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Shanghai
Validity to: Long-term effective
Last update: 2017-12-10 22:00
Browse the number: 273
inquiry
Company Profile
 
 
Product details


Performance Range : (50HZ and 60HZ)



1. Capacity : up to 250 m3/h  



2. Head : up to305m



3. Speed : up to 3600rpm



4. Power : up to 200kw



5. Voltage : 220V to 480V



6. Temperature range : Within 120 Deg C



8. Working pressure : Within 40bar






Application :



CDL/CDLF is vertical multistage pump which is multifunctional products. It can be used to convey various medium from tap water to industrial liquid at different temperature and with different flow rate and pressure. CDL type is applicable to conveying non-corrosive liquid, While CDLF is suitable for slightly corrosive liquid. 



Water supply: Water filter and transport in Waterworks, boosting of main pipeline, boosting in high-rise buildings. 



Industrial boosting: Process flow water system, cleaning system, high-pressure washing system, fire fighting system 



Industrial liquid conveying: Cooling and air-conditioning system, boiler water supply and condensing system, machine-associated purpose, acids and alkali 



Water treatment: Ultrafiltration system, reverse osmosis system, distillation system, swimming pool, separator 



Irrigation: Farmland irrigation, spray irrigation, dripping irrigation 






Operation Condition :



Thin, clean, non-flammable and non-explosive liquid containing no solid granules and fibers. 



Liquid temperature: 



Normal temperature type: -15~+70, 



Hot water type: +70~+120 



Ambient temperature: Up to +40 



Altitude: Up to 1000m 






Pump 



CDL/CDLF is a kind of vertical non-self priming multistage centrifugal pump, which is driven by a standard electric motor. The motor output shaft directly connects with the pump shaft through a coupling. The pressure-resistant cylinder and flow passage components are fixed between pump head and in-and outlet section with tie-bar bolts. The inlet and outlet are located at the pump bottom at the same plane. This kind of pump can be equipped with an intelligent protector to effectively prevent it from dry-running, out-of-phase and overload. 






Electric motor :



Full-enclosed air-blast two-pole standard motor 



Protection class: IP55 



Insulation class: F 



Standard voltage 



50Hz: 



1x220/230/240V 



3x220/380/415V                



3x380/400/415V 



60Hz: 



3X200/230



3x220/380/440V/460V