PublishYou are here: Home » Products » Machinery » Lathe

50L /100L /200L/300LGlass-Lined Reactor, F Type

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Shandong
Validity to: Long-term effective
Last update: 2017-12-03 10:07
Browse the number: 280
inquiry
Company Profile
 
 
Product details

F Type Glass-Lined Reactor
Main Features

1.The F type glass lined reactor comes with a one-piece design that the cover and body can not be separated. Due to that, a manhole has to be designed on the head of the reactor to make it easy for operators to enter the reactor to carry out maintenance and parts replacement.

2. It is a large capacity industrial process reactor, suitable for large scale production environment.

3. Similar to the K-type reactor, this type of chemical reactor is manufactured using TJ09 high end enamel and skilled enameling process. This enables the glass lining to be remarkably corrosion resistant, impact resistant and temperature variation resistant, combined with less prone to fracture and high durability.

4. Taiji is able to design and manufacture non standard glass lined reactor to user's requirements.

5. Our F type glass lined steel reactor comes in complete specifications, including F1500L, F2000L, F3000L, F4000L, F5000L, F6300L, F8000L, F10000L, F12500L, F16000L, F20000L, F30000L, F50000L, etc.

Parameter Test

Finished Product Inspection

Transportation

Transportation


Technical Parameters of the Glass-Lined Reactor
Design Drawing of F1500L-F6300L Glass-Lined Reactor


Internal Vessel

Jacket

Design Pressure(MPa)

0.4/0.6/1.0

0.6/1.0

Design Temperature( ℃ )

-19 ℃ /200℃

-19 ℃ /200℃

Symbol

Usage

a

Manhole

b

Agitator Hole

c

Thermowell

d, f, g, h

Spare

e

Sightglass

j

Medium Outlet

k1, k2, k3

In/Outlet

n1, n2, n3

Spray Nozzle

m

Vent Hole


Nozzle Design Drawing (Plan View)

Unit: mm

Specifications

F1500L

F2000L

F3000L

F4000L

F5000L

F6300L

Nominal Capacity (L)

1500

2000

3000

4000

5000

6300

Total Capacity (L)

2020

2470

3860

4795

6040

6900

Calculated Capacity(Notes 1) (L)

1990

2440

3830

4795

6016

6872

Jacket Capacity (L)

301

390

495

805

898

1015

Heat Exchange Area ( m2 )

5.92

7.31

9.98

12.44

14.06

16.36

Reference Weight (kg)

2120

2380

3360

3905

4720

5200

Main

Dimensions

d1

1300

1300

1600

1600

1750

1750

d2

1450

1450

1750

1750

1900

1900

d3(Notes 2)

1622

1622

1964

1964

2152

2152

d4

680

680

720

720

720

720

d5

700

700

800

800

850

850

h1

1801

2136

2250

2730

2888

3244

h2

190

190

190

190

190

190

h3

725

725

700

700

750

750

h4

975

975

1060

1060

1200

1200

B1

315

315

315

315

350

350

B2

510

510

510

510

510

510

Φ

30

30

30

30

30

30

Nozzle DN

a

300×400

300×400

300×400

300×400

300×400

300×400

b

125

125

150

150

150

150

c

100

100

100

100

125

125

d

100

100

100

100

125

125

e

125

125

125

125

125

125

f

125

125

125

125

150

150

g

100

100

100

100

125

125

h

125

125

125

125

150

150

j

100

100

125

125

125

125

Jacket

Nozzle DN

k1

40

40

65

65

65

65

k2

40

40

65

65

65

65

k3

40

40

65

65

65

65

n1

50

50

65

65

65

65

n2

/

/

/

65

65

65

n3

50

50

65

65

65

65

m

G3/8"

G3/8"

G3/8"

G3/8"

G3/8"

G3/8"

Drive

DN

80

80

95

95

95

95

h5

1320

1320

1360

1360

1360

1530

Notes 1: Calculated Capacity: Volume under highneck flange.

Notes 2: Types of support depend on users; if there is no special request, lugs would be normally applied.


Design Drawing of F8000L-F50000L Glass-Lined Reactor


Inner Vessel

Jacket

Design Pressure(MPa)

0.4/0.6/1.0

0.6/1.0

Design Temperature( ℃ )

-19 ℃ /200℃

-19 ℃ /200℃

Symbol

Usage

a

Medium Outlet

b1,b2,b3,b4

In/Outlet

c

Manhole

d

Agitator Hole

e1

Thermowell

e2, g1, g2, g3, g4, k

Spare

h

Sightglass

m

Vent Hole

n

Clean Hole


F50000L Nozzle Design (Plan View)

F8000L Nozzle Design (Plan View)

F10000L~F30000L Nozzle Design (Plan View)


Unit: mm

Specifications

F8000L

F10000L

F12500L

F16000L

F20000L

F30000L

F50000L

Nominal Capacity (L)

8000

10000

12500

16000

20000

30000

50000

Total Capacity (L)

9105

11719

13696

17491

21835

33645

56444

Calculated Capacity(Notes 1) (L)

9060

11674

13651

17446

21790

33500

55514

Jacket Capacity (L)

1666

1940

2243

2551

2870

3700

4520

Heat Exchange Area ( ㎡ )

18.38

21.35

24.89

29.48

34.04

45

34.04

Reference Weight (kg)

6959

7911

9342

11222

13530

19270

34590

Main

Dimension

d1

2000

2200

2200

2400

2600

3000

3800

d2

2200

2400

2400

2600

2800

3200

4000

d3(Notes 2)

2452

2703

2703

2908

3179

/

/

h1

3310

3533

4053

4346

4641

5340

5611

h2

210

210

210

210

210

260

647

h3

850

900

900

950

1000

1150

1340

h4

1200

1300

1300

1400

1550

/

/

h

5400

5600

6530

7010

7475

8835

10425

B1

400

470

470

470

470

470

470

B2

510

550

550

550

550

550

550

Φ

30

36

36

36

36

/

/

Nozzle DN

a

125

150

150

150

150

150

150

c

300×400

300×400

300×400

450

450

450

450

d

200

200

200

200

250

250

250

e1

200

200

200

200

200

200

200

e2

150

200

200

200

200

200

200

e3

/

/

/

/

/

/

200

g1

150

150

150

150

150

150

150

g2

150

150

150

150

150

150

150

g3

/

150

150

150

150

150

150

g4

150

150

150

150

150

150

150

h

125

125

125

125

125

125

125

k

125

125

125

125

125

125

125

Jacket

Nozzle DN

b1

65

80

80

100

100

100

125

b2

65

80

80

100

100

100

125

b3

65

80

80

100

100

100

125

b4

/

80

80

100

100

100

100

f1

65

80

80

100

100

100

100

f2

65

80

80

100

100

100

100

f3

65

80

80

100

100

100

100

m

G3/4"

G3/4"

G3/4"

G3/4"

G3/4"

G3/4"

G3/4"

n

G1/2"

G1/2"

G1/2"

G1/2"

G1/2"

G1/2"

G1/2"

Drive

DN

110

110

110

130

140

160

160

h5

1375

1375

1375

1995

2190

2420

2640

Notes 1: Calculated Capacity: Volume under highneck flange.

Notes 2: Support types could be determined by users; if there is no special request, lugs would be normally applied.


Samples Show

Upper Structure


Manhole with Sight Glass


Bottom Outlet


Bottom View


Side View

Front View

Production Line



Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]